Matrix

- DELIVERY- IMMEDIATE to 3 DAYS
- Durable and Reliable
- Made in-house
Number of inputs : 2
Separation of channels : electrically isolation (>2kV)
Input range : +/- 10 VDC (probably other ranges too)
Resolution : 16 Bit
Signal quality: HW and SW filter combined to 10Hz
Time : internal RTC, set by PC during programming
Sampling rate : variable starting at 1/10th of a second
Power input : Battery operated (probably extension pack)
Max recording time : 3 days (over a weekend)
Data Transfer to Computer : e.g. SD-Memory card
Enclosure : IP64, has to fit in a 3” Pipe
Programming of Logger : Through PC, RS232 or IR
Status indicators : LED’s – Power, Logging, Programmed, Finished
Memory calculation
- 3 Days
- 86400 seconds per day
- 10 readings per second
- 2 channels
- 2 Bytes per channel per readings (16 Bit)
- 3*86400*10*2*2
- 10,368,000 Bytes = 9.89 MB